Small-sized Industrial Unit

Deutsch | English

  • Power flow: to component
  • Maximum power: 8.4 kVA
  • Connected to: AC network

Symmetrical load in Y-connection

Three programmable loads with 2.8 kVA each

Phase shifting of ±90° possible by virtue of variable resistance

Phase shifting creates harmonics due to current cufoff occuring at the voltage zero-crossing and no available reactances

  • Fig. 1: Representation of the small-sized industrial unit

Various AC loads can be simulated

Load curves computed as stochastic time profiles within Matlab/Simulink

Value of collective load current is the control variable sent to the electronic devices

By use of master-slave-connection the respective current values are allocated to the specific units

  • Fig. 2: Scheme of the small-sized industrial unit

Specific informationen on the functionality and the operation of the small-sized industrial unit are provided at the lab-internal wiki site:
http://130.149.206.221/redmine/projects/senselab/wiki/Industry